Digital Radiographic System |
|
Product
code:
Origin:
Warranty:
|
|
Share with:
|
|
|
|
|
|
|
Specifications
Related Products
GENEROR Milestone HF  Specifications | | Power Rating | 30-80 kW | | kV range | 40-150 kVp | | mA range | 20-1000 mA (depending on the generator power) | | mAs range | 0.4-600 mAs | | Exposure time | 3 ms-6 sec. | | Fluoroscopic kV | 40-120 kV | | Fluoroscopic mA | 0.5-10 mA (25 mA in Pulse Fluoroscopy) | | Power Requirements | From 240 VAC single to 480 three phase | Features | | - Microprocessor control delivers reliability and accurate exposure parameter management.
- APR operating mode with 100 examination distributed across 10 anatomical regions. Simple and user-friendly technique reprogramming on site.
- Manual three factor factor selection permits the operator to modify the recommended kV, mA and time.
- Easy Auto-Calibration reduces initial installation time.
- Automatic tube protection.
- Sophisticated self-diagnostic capability and coded error messaged allow for fast and well-defined initial diagnostics.
- Compact console is ideally suited for small control rooms.
- Automatic tube overload protection, selectable 80% or 100%.
- Automatic Exposure Control can support either four solid state detectors or ion chambers.
- Automatic Brightness Stabilizer produces optimal fluoroscopic images.
- Supports one or two x-ray tubes in either radiographic or radiographic and fluoroscopic mode.
Generator PCX HF Specifications | | Power Rating | 30-80 kW | | kV range | 40-150 kVp | | mA range | 20-1000 mA (depending on the generator power) | | mAs range | 0.4-600 mAs | | Exposure time | 3 ms-6 sec. | | Fluoroscopic kV | 40-120 kV | | Fluoroscopic mA | 0.5-10 mA (25 mA in Pulse Fluoroscopy) | | Power Requirements | From 240 VAC single to 480 three phase | Features | | - Microcontroller and computer integration deliver reliability and accurate exposure parameter management.
- APR operating mode with 160 examination distributed across 8 anatomical regions. Simple and user-friendly technique reprogramming on site.
- Automatic parameter correction for patient thickness, tissue density, film.screen speed and source image distance.
- Manual override technology permits the operator to modify the recommended kV, mA and time.
- Sophisticated self-diagnostic capability and descriptive error messaged allow for fast and well-defined initial diagnostics.
- Compact display console is ideally suited for small control rooms.
- Comprehensive service program provides accurate troubleshooting and minimize downtime.
- Automatic tube overload protection, selectable 80% or 100%.
- Automatic Exposure Control can support either four solid state detectors or ion chambers.
- Automatic Brightness Stabilizer produces optimal fluoroscopic images.
- Supports one or two x-ray tubes in either radiographic or radiographic and fluoroscopic mode.
 | | | Z-Motion Digital Stand Specifications | | Power Rating | 30-80 kW | | kV range | 40-150 kVp | | mA range | 20-1000 mA (depending on the generator power) | | mAs range | 0.4-600 mAs | | Exposure time | 3 ms-6 sec. | | Fluoroscopic kV | 40-120 kV | | Fluoroscopic mA | 0.5-10 mA (25 mA in Pulse Fluoroscopy) | | Power Requirements | From 240 VAC single to 480 three phase | Features | | - Microcontroller and computer integration deliver reliability and accurate exposure parameter management.
- APR operating mode with 160 examination distributed across 8 anatomical regions. Simple and user-friendly technique reprogramming on site.
- Automatic parameter correction for patient thickness, tissue density, film.screen speed and source image distance.
- Manual override technology permits the operator to modify the recommended kV, mA and time.
- Sophisticated self-diagnostic capability and descriptive error messaged allow for fast and well-defined initial diagnostics.
- Compact display console is ideally suited for small control rooms.
- Comprehensive service program provides accurate troubleshooting and minimize downtime.
- Automatic tube overload protection, selectable 80% or 100%.
- Automatic Exposure Control can support either four solid state detectors or ion chambers.
- Automatic Brightness Stabilizer produces optimal fluoroscopic images.
- Supports one or two x-ray tubes in either radiographic or radiographic and fluoroscopic mode.
|
|
| |
|
 |
|